@@ -382,30 +382,22 @@ namespace OTSIncAReportGraph.OTSIncAReportGraphFuncation
|
|
|
/// </summary>
|
|
|
public void Connection_ForDrawDistrbutionImageAndBSE()
|
|
|
{
|
|
|
- string str1 = "分布图准备开始连接SEM电镜";
|
|
|
- str1 = table["str1"].ToString();
|
|
|
- log.Trace("(Connection_ForDrawDistrbutionImageAndBSE)" + str1);
|
|
|
+ log.Trace("(Connection_ForDrawDistrbutionImageAndBSE)" + "Distribution map ready to start connecting SEM");
|
|
|
if (!m_SEMConnectionState)
|
|
|
{
|
|
|
|
|
|
//和电镜建立通讯连接
|
|
|
m_SEMConnectionState = m_cfun.ConncetSem();
|
|
|
- string str2 = "调用连接后状态";
|
|
|
- str2 = table["str2"].ToString();
|
|
|
- log.Trace("(Connection_ForDrawDistrbutionImageAndBSE)" + str2 + ":--" + m_SEMConnectionState + "---");
|
|
|
+ log.Trace("(Connection_ForDrawDistrbutionImageAndBSE)" + "State after calling the connection" + ":--" + m_SEMConnectionState + "---");
|
|
|
|
|
|
///获取当前电镜的ID号
|
|
|
m_SEM_ID = m_cfun.GetSemType();
|
|
|
- string str3 = "获得电镜的ID";
|
|
|
- str3 = table["str3"].ToString();
|
|
|
- log.Trace("(Connection_ForDrawDistrbutionImageAndBSE)" + str3 + ":--" + m_SEM_ID.ToString() + "---");
|
|
|
+ log.Trace("(Connection_ForDrawDistrbutionImageAndBSE)" + "The ID of electron microscope obtained" + ":--" + m_SEM_ID.ToString() + "---");
|
|
|
}
|
|
|
else
|
|
|
{
|
|
|
//断开电镜连接
|
|
|
- string str4 = "电镜是已经连接的状态,准备断开";
|
|
|
- str4 = table["str4"].ToString();
|
|
|
- log.Trace("(Connection_ForDrawDistrbutionImageAndBSE)" + str4 + ":--" + m_SEMConnectionState + "---");
|
|
|
+ log.Trace("(Connection_ForDrawDistrbutionImageAndBSE)" + "The electron microscope is in a connected state and ready to disconnect" + ":--" + m_SEMConnectionState + "---");
|
|
|
//if (m_cfun.DisConnectSem())
|
|
|
//{
|
|
|
// string str5 = "电镜是已经连接的状态,完成断开后状态";
|
|
|
@@ -420,31 +412,23 @@ namespace OTSIncAReportGraph.OTSIncAReportGraphFuncation
|
|
|
/// </summary>
|
|
|
public void Connection_ForDrawDistrbutionSortImage()
|
|
|
{
|
|
|
- string str6 = "分布图准备开始连接SEM电镜";
|
|
|
- str6 = table["str6"].ToString();
|
|
|
- log.Trace("(Connection_ForDrawDistrbutionImageAndBSE)" + str6);
|
|
|
+ log.Trace("(Connection_ForDrawDistrbutionImageAndBSE)" + "Distribution map ready to start connecting SEM");
|
|
|
if (!m_SEMConnectionState)
|
|
|
{
|
|
|
m_cfun = new COTSControlFunExport();//重新new一下试试呢,不New并不好用 It's better to reinitialize, but it's not good to uninitialize
|
|
|
|
|
|
//和电镜建立通讯连接
|
|
|
m_SEMConnectionState = m_cfun.ConncetSem();
|
|
|
- string str7 = "调用连接后状态";
|
|
|
- str7 = table["str7"].ToString();
|
|
|
- log.Trace("(Connection_ForDrawDistrbutionImageAndBSE)" + str7 + ":--" + m_SEMConnectionState + "---");
|
|
|
+ log.Trace("(Connection_ForDrawDistrbutionImageAndBSE)" + "State after calling the connection" + ":--" + m_SEMConnectionState + "---");
|
|
|
|
|
|
///获取当前电镜的ID号
|
|
|
m_SEM_ID = m_cfun.GetSemType();
|
|
|
- string str8 = "获得电镜的ID";
|
|
|
- str8 = table["str8"].ToString();
|
|
|
- log.Trace("(Connection_ForDrawDistrbutionImageAndBSE)" + str8 + ":--" + m_SEM_ID.ToString() + "---");
|
|
|
+ log.Trace("(Connection_ForDrawDistrbutionImageAndBSE)" + "The ID of electron microscope obtained" + ":--" + m_SEM_ID.ToString() + "---");
|
|
|
}
|
|
|
else
|
|
|
{
|
|
|
//断开电镜连接
|
|
|
- string str9 = "电镜是已经连接的状态,准备断开";
|
|
|
- str9 = table["str9"].ToString();
|
|
|
- log.Trace("(Connection_ForDrawDistrbutionImageAndBSE)str9:--" + m_SEMConnectionState + "---");
|
|
|
+ log.Trace("(Connection_ForDrawDistrbutionImageAndBSE)" + "The electron microscope is in a connected state and ready to disconnect" + ":--" + m_SEMConnectionState + "---");
|
|
|
//if (m_cfun.DisConnectSem())
|
|
|
//{
|
|
|
// string str10 = "电镜是已经连接的状态,完成断开后状态";
|
|
|
@@ -461,9 +445,7 @@ namespace OTSIncAReportGraph.OTSIncAReportGraphFuncation
|
|
|
/// <param name="PositionY"></param>
|
|
|
public void MoveSemToPointXY_ForDrawDistrbutionImageAndBSE(double in_PositionX, double in_PositionY)
|
|
|
{
|
|
|
- string str11 = "分布图准备开始移动电镜到";
|
|
|
- str11 = table["str11"].ToString();
|
|
|
- log.Trace("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + str11);
|
|
|
+ log.Trace("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + "DistrbutionImage is ready to move Sem to");
|
|
|
|
|
|
//首先获取电镜当前的位置,并记录原R值
|
|
|
double ls_PositionX = 0;
|
|
|
@@ -473,29 +455,21 @@ namespace OTSIncAReportGraph.OTSIncAReportGraphFuncation
|
|
|
if (m_SEMConnectionState)
|
|
|
{
|
|
|
m_cfun.GetSemPositionXY(ref ls_PositionX, ref ls_PositionY, ref ls_PositionR);
|
|
|
- string str12 = "获取原先电镜位置为X";
|
|
|
- str12 = table["str12"].ToString();
|
|
|
- log.Trace("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + str12 + ":" + ls_PositionX.ToString() + " Y:" + ls_PositionY.ToString() + " R:" + ls_PositionR.ToString());
|
|
|
+ log.Trace("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + "Obtain the original electron microscope position as X" + ":" + ls_PositionX.ToString() + " Y:" + ls_PositionY.ToString() + " R:" + ls_PositionR.ToString());
|
|
|
}
|
|
|
else
|
|
|
{
|
|
|
- string str13 = "获取电镜位置时状态错误";
|
|
|
- str13 = table["str13"].ToString();
|
|
|
- log.Error("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + str13);
|
|
|
+ log.Error("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + "Error obtaining electron microscope position");
|
|
|
}
|
|
|
|
|
|
if (m_SEMConnectionState)
|
|
|
{
|
|
|
m_cfun.MoveSEMToPoint(in_PositionX, in_PositionY, ls_PositionR);
|
|
|
- string str14 = "移动电镜到指定位置";
|
|
|
- str14 = table["str14"].ToString();
|
|
|
- log.Trace("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + str14 + ":" + in_PositionX.ToString() + " Y:" + in_PositionY.ToString() + " R:" + ls_PositionR.ToString());
|
|
|
+ log.Trace("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + "Move electron microscope to specified position" + ":" + in_PositionX.ToString() + " Y:" + in_PositionY.ToString() + " R:" + ls_PositionR.ToString());
|
|
|
}
|
|
|
else
|
|
|
{
|
|
|
- string str15 = "移动电镜时状态错误";
|
|
|
- str15 = table["str15"].ToString();
|
|
|
- log.Error("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + str15);
|
|
|
+ log.Error("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + "Status error while moving electron microscope");
|
|
|
}
|
|
|
}
|
|
|
|
|
|
@@ -506,9 +480,7 @@ namespace OTSIncAReportGraph.OTSIncAReportGraphFuncation
|
|
|
/// <param name="PositionY"></param>
|
|
|
public void MoveSemToPointXY_ForDrawDistrbutionSortImage(double in_PositionX, double in_PositionY)
|
|
|
{
|
|
|
- string str16 = "分布图准备开始移动电镜到";
|
|
|
- str16 = table["str16"].ToString();
|
|
|
- log.Trace("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + str16);
|
|
|
+ log.Trace("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + "DistrbutionImage is ready to move Sem to");
|
|
|
|
|
|
//首先获取电镜当前的位置,并记录原R值
|
|
|
double ls_PositionX = 0;
|
|
|
@@ -517,30 +489,21 @@ namespace OTSIncAReportGraph.OTSIncAReportGraphFuncation
|
|
|
|
|
|
if (m_SEMConnectionState)
|
|
|
{
|
|
|
- string str17 = "获取原先电镜位置为X";
|
|
|
- str17 = table["str17"].ToString();
|
|
|
- m_cfun.GetSemPositionXY(ref ls_PositionX, ref ls_PositionY, ref ls_PositionR);
|
|
|
- log.Trace("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + str17 + ":" + ls_PositionX.ToString() + " Y:" + ls_PositionY.ToString() + " R:" + ls_PositionR.ToString());
|
|
|
+ log.Trace("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + "Obtain the original electron microscope position as X" + ":" + ls_PositionX.ToString() + " Y:" + ls_PositionY.ToString() + " R:" + ls_PositionR.ToString());
|
|
|
}
|
|
|
else
|
|
|
{
|
|
|
- string str18 = "获取电镜位置时状态错误";
|
|
|
- str18 = table["str18"].ToString();
|
|
|
- log.Error("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + str18);
|
|
|
+ log.Error("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + "Error obtaining electron microscope position");
|
|
|
}
|
|
|
|
|
|
if (m_SEMConnectionState)
|
|
|
{
|
|
|
m_cfun.MoveSEMToPoint(in_PositionX, in_PositionY, ls_PositionR);
|
|
|
- string str19 = "移动电镜到指定位置";
|
|
|
- str19 = table["str19"].ToString();
|
|
|
- log.Trace("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + str19 + ":" + in_PositionX.ToString() + " Y:" + in_PositionY.ToString() + " R:" + ls_PositionR.ToString());
|
|
|
+ log.Trace("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + "Move electron microscope to specified position" + ":" + in_PositionX.ToString() + " Y:" + in_PositionY.ToString() + " R:" + ls_PositionR.ToString());
|
|
|
}
|
|
|
else
|
|
|
{
|
|
|
- string str20 = "移动电镜时状态错误";
|
|
|
- str20 = table["str20"].ToString();
|
|
|
- log.Error("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + str20);
|
|
|
+ log.Error("(MoveSemToPointXY_ForDrawDistrbutionImageAndBSE)" + "Status error while moving electron microscope");
|
|
|
}
|
|
|
}
|
|
|
|
|
|
@@ -549,18 +512,14 @@ namespace OTSIncAReportGraph.OTSIncAReportGraphFuncation
|
|
|
/// </summary>
|
|
|
public void DisConnectSEM_ForDrawDistrbutionImageAndBSE()
|
|
|
{
|
|
|
- string str21 = "准备关闭电镜连接";
|
|
|
- str21 = table["str21"].ToString();
|
|
|
- log.Trace("(DisConnectSEM_ForDrawDistrbutionImageAndBSE)" + str21);
|
|
|
+ log.Trace("(DisConnectSEM_ForDrawDistrbutionImageAndBSE)" + "Prepare to close the SEM link");
|
|
|
//if (m_cfun.DisConnectSem() == true)
|
|
|
//{
|
|
|
// string str22 = "准备关闭电镜连接";
|
|
|
// str22 = table["str22"].ToString();
|
|
|
// log.Trace("(DisConnectSEM_ForDrawDistrbutionImageAndBSE)" + str22);
|
|
|
//}
|
|
|
- string str23 = "准备释放DLL";
|
|
|
- str23 = table["str23"].ToString();
|
|
|
- log.Trace("(DisConnectSEM_ForDrawDistrbutionImageAndBSE)" + str23);
|
|
|
+ log.Trace("(DisConnectSEM_ForDrawDistrbutionImageAndBSE)" + "Preparing to free the DLL");
|
|
|
//m_cfun.FreeHardware();
|
|
|
|
|
|
m_SEMConnectionState = false;
|
|
|
@@ -571,16 +530,12 @@ namespace OTSIncAReportGraph.OTSIncAReportGraphFuncation
|
|
|
/// </summary>
|
|
|
public void DisConnectSEM_ForDrawDistrbutionSortImage()
|
|
|
{
|
|
|
- string str24 = "准备关闭电镜连接";
|
|
|
- str24 = table["str24"].ToString();
|
|
|
- log.Trace("(DisConnectSEM_ForDrawDistrbutionImageAndBSE)" + str24);
|
|
|
+ log.Trace("(DisConnectSEM_ForDrawDistrbutionImageAndBSE)" + "Prepare to close the SEM link");
|
|
|
//if (m_cfun.DisConnectSem() == true)
|
|
|
//{
|
|
|
// log.Trace("(DisConnectSEM_ForDrawDistrbutionImageAndBSE)" + str24);
|
|
|
//}
|
|
|
- string str25 = "准备释放DLL";
|
|
|
- str25 = table["str25"].ToString();
|
|
|
- log.Trace("(DisConnectSEM_ForDrawDistrbutionImageAndBSE)" + str25);
|
|
|
+ log.Trace("(DisConnectSEM_ForDrawDistrbutionImageAndBSE)" + "Preparing to free the DLL");
|
|
|
m_cfun.FreeHardware();
|
|
|
|
|
|
m_SEMConnectionState = false;
|