IncADataDB.cs 10 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187
  1. using System;
  2. using System.Collections.Generic;
  3. using System.Data;
  4. using System.Diagnostics;
  5. using System.Drawing;
  6. using System.Linq;
  7. using System.Text;
  8. using System.Threading.Tasks;
  9. using System.Windows;
  10. using OTSCLRINTERFACE;
  11. using OTSDataType;
  12. using OTSModelSharp.DTLBase;
  13. namespace OTSModelSharp
  14. {
  15. public class CIncADataDB : CSQLiteDB
  16. {
  17. public CIncADataDB(IDBStoreBase _conStr, IDBTableBase _table) : base(_conStr, _table)
  18. {
  19. }
  20. public bool UpdataAIncA(COTSParticleClr a_pParticle)
  21. {
  22. if (a_pParticle == null)
  23. {
  24. return false;
  25. }
  26. var datastorePtr = GetDatastore();
  27. string sSQLCommand = "Update IncAData set AveGray = {0},Area ={1},IncAId={2} where FieldID = {3} and ParticleId = {4} "; //sSQLCommand.Format(sSQLCommand,a_pParticle->GetAveGray(),a_pParticle->GetArea(),a_pParticle->GetType(),a_pParticle->GetFieldId(),a_pParticle->GetTagId());
  28. sSQLCommand = string.Format(sSQLCommand, a_pParticle.GetAveGray(), a_pParticle.GetArea(), a_pParticle.GetType(), a_pParticle.GetFieldId(), a_pParticle.GetTagId());
  29. var ret = datastorePtr.RunCommand( sSQLCommand);
  30. return ret;
  31. }
  32. public bool SaveAIncA(COTSParticleClr a_pParticle, System.Drawing.Point fldPos)
  33. {
  34. var tableInfoPtr = GetTableInfo();
  35. if (tableInfoPtr==null)
  36. {
  37. return false;
  38. }
  39. var datastorePtr = GetDatastore();
  40. string sInsertFormat = tableInfoPtr.GetInsertCommandFormatString(true);
  41. string sSQLCommand;
  42. Rectangle rec = (Rectangle)a_pParticle.GetParticleRect();
  43. System.Drawing.Point xrayPos = (System.Drawing.Point)a_pParticle.GetXRayPos();
  44. System.Drawing.Point semPos = (System.Drawing.Point)a_pParticle.GetAbsolutPos();
  45. sSQLCommand =string.Format(sInsertFormat, a_pParticle.GetFieldId(), a_pParticle.GetAnalysisId(), a_pParticle.GetAveGray(), rec.Left, rec.Top, rec.Width, rec.Height, a_pParticle.GetArea(), xrayPos.X, xrayPos.Y, a_pParticle.GetClassifyId(), 0, (int)(a_pParticle.GetFeature().GetSegmentsList().Count), fldPos.X, fldPos.Y, a_pParticle.GetTagId(), a_pParticle.GetDMAX(), a_pParticle.GetDMIN(), a_pParticle.GetDMPERP(), a_pParticle.GetDPRIMETER(), a_pParticle.GetORIENTATION(), a_pParticle.GetDINSCR(), a_pParticle.GetDMEAN(), a_pParticle.GetDELONG(), a_pParticle.GetFeretDiameter(), a_pParticle.GetTypeName(), a_pParticle.GetTypeColor(),semPos.X,semPos.Y);
  46. if (!datastorePtr.RunCommand(sSQLCommand))
  47. {
  48. return false;
  49. }
  50. return true;
  51. }
  52. public bool GetAllFieldsRecord(ref List<COTSFieldData> allFlds)
  53. {
  54. var allRecords = this.GetQueryOfAllRecord();
  55. Dictionary<int, COTSFieldData> mapFld = new Dictionary<int, COTSFieldData>(); //std.map<int, COTSFieldDataPtr> mapFld = new std.map<int, COTSFieldDataPtr>();
  56. for (int i = 0; i < allRecords.Rows.Count; i++)
  57. {
  58. int curFldId = Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_FIELD_ID]); //GetColIntValue((int)CIncADataTable.ColumnID.N_FIELD_ID);
  59. if (!mapFld.Keys.Contains(curFldId))
  60. {
  61. COTSFieldData fld = new COTSFieldData();
  62. fld.SetId(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_PARTICLE_ID]));
  63. System.Drawing.Point fldPos =new System.Drawing.Point();
  64. fldPos.X = Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_FldPosX]);
  65. fldPos.Y = Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_FldPosY]);
  66. fld.SetPosition(fldPos);
  67. List<COTSParticleClr> ps = fld.GetListAnalysisParticles();
  68. COTSParticleClr p = new COTSParticleClr();
  69. p.SetFieldId(fld.GetId());
  70. p.SetTagId(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_PARTICLE_ID]));
  71. p.SetType(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_INCA_ID]));
  72. int top = Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_RECT_TOP]);
  73. int left = Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_RECT_LEFT]);
  74. int width = Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_RECT_WIDTH]);
  75. int height = Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_RECT_HEIGHT]);
  76. Rectangle r = new Rectangle(left, top, left + width, top + height);
  77. p.SetParticleRect(r);
  78. p.SetSubParticles("");
  79. p.SetAveGray(Convert.ToByte(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_AVE_GRAY]));
  80. p.SetArea(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.F_AREA]));
  81. p.SetAnalysisId(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_XRAY_ID]));
  82. p.SetDMAX(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.F_DMAX]));
  83. p.SetDMIN(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.F_DMIN]));
  84. p.SetDMPERP(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.F_DPERP]));
  85. p.SetDINSCR(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.F_DINSCR]));
  86. p.SetDMEAN(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.F_DMEAN]));
  87. p.SetDELONG(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.F_DELONG]));
  88. p.SetDPRIMETER(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.F_PERIMETER]));
  89. p.SetORIENTATION(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.F_ORIENTATION]));
  90. p.SetTypeName(allRecords.Rows[i][(int)CIncADataTable.ColumnID.S_NAME].ToString());
  91. p.SetTypeColor(allRecords.Rows[i][(int)CIncADataTable.ColumnID.S_COLOR].ToString());
  92. ps.Add(p);
  93. allFlds.Add(fld);
  94. mapFld[curFldId] = fld;
  95. }
  96. else
  97. {
  98. COTSFieldData fld = mapFld[curFldId];
  99. List<COTSParticleClr> ps = fld.GetListAnalysisParticles();
  100. COTSParticleClr p = new COTSParticleClr();
  101. p.SetFieldId(fld.GetId());
  102. p.SetTagId(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_PARTICLE_ID]));
  103. p.SetType(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_INCA_ID]));
  104. int top = Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_RECT_TOP]);
  105. int left = Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_RECT_LEFT]);
  106. int width = Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_RECT_WIDTH]);
  107. int height = Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_RECT_HEIGHT]);
  108. Rectangle r = new Rectangle(left, top, left + width, top + height);
  109. p.SetParticleRect(r);
  110. //p.SetSubParticles("");
  111. p.SetAveGray(Convert.ToByte(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_AVE_GRAY]));
  112. p.SetArea(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.F_AREA]));
  113. p.SetAnalysisId(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.N_XRAY_ID]));
  114. p.SetDMAX(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.F_DMAX]));
  115. p.SetDMIN(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.F_DMIN]));
  116. p.SetDMPERP(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.F_DPERP]));
  117. p.SetDINSCR(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.F_DINSCR]));
  118. p.SetDMEAN(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.F_DMEAN]));
  119. p.SetDELONG(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.F_DELONG]));
  120. p.SetDPRIMETER(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.F_PERIMETER]));
  121. p.SetORIENTATION(Convert.ToInt32(allRecords.Rows[i][(int)CIncADataTable.ColumnID.F_ORIENTATION]));
  122. p.SetTypeName(allRecords.Rows[i][(int)CIncADataTable.ColumnID.S_NAME].ToString());
  123. p.SetTypeColor(allRecords.Rows[i][(int)CIncADataTable.ColumnID.S_COLOR].ToString());
  124. ps.Add(p);
  125. }
  126. }
  127. return true;
  128. }
  129. protected DataTable GetQueryById(int a_nXrayId, int a_nFieldId)
  130. {
  131. CSQLiteTable query = new CSQLiteTable();
  132. var datastorePtr = GetDatastore();
  133. var tableInfoPtr = GetTableInfo();
  134. string sXrayIdColumnName = tableInfoPtr.GetColumnName((int)CIncADataTable.ColumnID.N_XRAY_ID - (int)CIncADataTable.ColumnID.MIN); //tableInfoPtr.GetColumnName((int)CIncADataTable.ColumnID.N_XRAY_ID - (int)CIncADataTable.ColumnID.MIN);
  135. string sFieldIdColumnName = tableInfoPtr.GetColumnName((int)CIncADataTable.ColumnID.N_FIELD_ID - (int)CIncADataTable.ColumnID.MIN); //tableInfoPtr.GetColumnName((int)CIncADataTable.ColumnID.N_FIELD_ID - (int)CIncADataTable.ColumnID.MIN);
  136. string sSQLCommand=string.Format("SELECT * FROM \'{0}\' WHERE {1} = {2} AND %s = {3};", (string)tableInfoPtr.GetTableName(), (string)sFieldIdColumnName, a_nFieldId, (string)sXrayIdColumnName, a_nXrayId);
  137. DataTable t1 =datastorePtr.QueryByCmdForDataTable(sSQLCommand);
  138. return t1;
  139. }
  140. protected DataTable GetQueryOfAllRecord()
  141. {
  142. var datastorePtr = GetDatastore();
  143. var tableInfoPtr = GetTableInfo();
  144. string sSQLCommand= string.Format("SELECT * FROM \'{0}\';", (string)tableInfoPtr.GetTableName());
  145. DataTable t1 = datastorePtr.QueryByCmdForDataTable(sSQLCommand);
  146. return t1;
  147. }
  148. }
  149. }